• Nash Peake Works,Tunstall, Stoke-on-Trent, ST6 5BT England

Steeplejacks Reserved For Christmas Shutdown

A valued customer based in Gloucestershire UK has awarded Rafferty’s a contract to carry out external and internal maintenance works on a 30m high brick chimney during the Christmas period.

The external maintenance work includes pointing of fractures and re-painting of external steelwork. The internal maintenance work includes a washdown and partial demolition and re-building of the internal refractory brick lining. The internal brick lining repairs are crucial to the sites production for the new year so a strict planning schedule has been implemented to ensure that the shutdown dates are achieved.

Finally, when you are enjoying the festivities this year please spare a thought for the steeplejacks working up high amongst the soot of the chimneys around the UK. For these hardy men it will definitely not be a white Christmas!

Read More

Northern Ireland Contract Complete

Rafferty’s have successfully completed structural repair works to a 73.2m high steel chimney in the Northern Ireland.

A re-design and feasibility study of the structure was initially carried out which revealed that structural modifications and repairs were required to ensure the structural integrity of the chimney. This involved installing stiffening steelwork between the 20m and 24m level along with removing the existing helical strake wind stabilers and replacing them with a liquid filled stabilising damper system. 

A team of 3 steeplejacks and welder platers successfully completed the project to the complete satisfaction of the client and without any disruption to the operating conditions of the chimney.

The following photographs outline the works carried out.

Read More

London Contract Secured

Rafferty’s have secured a sizable contract to carry out maintenance works on 2 No. 89m high twin flue steel chimneys and 1 No. 33m high multi flue steel chimney for a valued customer in London, UK.

The maintenance works are planned to start at the end of September and will require a specialised team of steeplejack operatives for a duration of nearly 8 weeks.

Read More

ISO 9001:2008

Following a recent external quality audit, Rafferty’s have been informed that they will achieve ISO 9001:2008 accreditation for a 12th year running. The certificate of registration will soon be posted on our website.

Rafferty’s would like to congratulate its management team for their hard work in maintaining this notable accreditation.

Read More

Emergency Repair Works Complete UK Power Plant

Rafferty’s have successfully completed emergency structural repair works to 2 No. steel chimneys on a Power Plant in the South West of England.

The 65m high x 6.3m diameter stacks had suffered corrosion attack and deterioration to the steel shell which required immediate structural plating works. An innovative scaffolding arrangement enabled safe access for our steeplejack and welder plater operatives to undertake the works from both inside and outside of the structures throughout their full circumference.

Rafferty’s highly specialised workforce along with their vast experience of structural repairs to steel chimney structures proved paramount on this project. Our swift and professional approach ensured the future structural integrity of these chimneys, much to the relief of our valued client.

The following photographs show the typical defects located and our steeplejacks and welder platers at work. Please click on the images to enlarge.

Read More

Steel Chimney Modifications Complete

Rafferty’s have successfully completed structural modifications and repairs on a 37m high steel chimney for a valued client in the North West of England.

A re-design and feasibility study of the structure was initially carried out which revealed that modifications and repairs were required to ensure the structural integrity of the chimney. The modifications included removing the existing helical strake wind stabilisers and replacing them with a liquid filled stabilising damper system. Steel stiffening work was also carried out to an area of the chimney shell below roof level. Repair works included replacing areas of the internal gunite lining which had previously failed. A team of steeplejacks and welder platers successfully completed the project to the complete satisfaction of the client.

Read More